Naylor, David
Permanent URI for this collection
Browse
Browsing Naylor, David by Subject "Fourier transform spectroscopy"
Now showing 1 - 4 of 4
Results Per Page
Sort Options
- ItemCalibration of Herschel SPIRE FTS observations at different spectral resolutions(Oxford University Press, 2017) Marchili, N.; Hopwood, R.; Fulton, T.; Polehampton, E. T.; Valtchanov, I.; Zaretski, J.; Naylor, David A.; Griffin, M. J.; Imhof, P.; Lim, T.; Lu, N.; Makiwa, G.; Pearson, C.; Spencer, Locke DeanThe SPIRE Fourier Transform Spectrometer on-board the Herschel Space Observatory had two standard spectral resolution modes for science observations: high resolution (HR) and low resolution (LR), which could also be performed in sequence (H+LR). A comparison of the HR and LR resolution spectra taken in this sequential mode revealed a systematic discrepancy in the continuum level. Analysing the data at different stages during standard pipeline processing demonstrates that the telescope and instrument emission affect HR and H+LR observations in a systematically different way. The origin of this difference is found to lie in the variation of both the telescope and instrument response functions, while it is triggered by fast variation of the instrument temperatures. As it is not possible to trace the evolution of the response functions using housekeeping data from the instrument subsystems, the calibration cannot be corrected analytically. Therefore, an empirical correction for LR spectra has been developed, which removes the systematic noise introduced by the variation of the response functions.
- ItemCalibration of the Herschel SPIRE Fourier Transform Spectrometer(Oxford University Press, 2014) Swinyard, B. M.; Polehampton, E. T.; Hopwood, R.; Valtchanov, I.; Lu, N.; Fulton, T.; Benielli, D.; Imhof, P.; Marchili, N.; Baluteau, J.-P.; Bendo, G. J.; Ferlet, M.; Griffin, M. J.; Lim, T. L.; Makiwa, G.; Naylor, David A.; Orton, G. S.; Papageorgiou, A.; Pearson, C. P.; Schulz, B.; Sidher, S. D.; Spencer, Locke Dean; van der Wiel, M. H. D.; Wu, R.The Herschel Spectral and Photometric REceiver (SPIRE) instrument consists of an imaging photometric camera and an imaging Fourier Transform Spectrometer (FTS), both operating over a frequency range of∼450–1550GHz. In this paper, we briefly review the FTS design, operation, and data reduction, and describe in detail the approach taken to relative calibration (removal of instrument signatures) and absolute calibration against standard astronomical sources. The calibration scheme assumes a spatially extended source and uses the Herschel telescopeasprimarycalibrator.Conversionfromextendedtopoint-sourcecalibrationiscarried out using observations of the planet Uranus. The model of the telescope emission is shown to beaccuratetowithin6percent andrepeatable tobetterthan0.06percent and,bycomparison with models of Mars and Neptune, the Uranus model is shown to be accurate to within 3 per cent. Multiple observations of a number of point-like sources show that the repeatability of the calibration is better than 1 per cent, if the effects of the satellite absolute pointing error (APE) are corrected. The satellite APE leads to a decrement in the derived flux, which can be up to∼10 per cent (1 σ) at the high-frequency end of the SPIRE range in the first part of the mission, and∼4 per cent after Herschel operational day 1011. The lower frequency range of the SPIRE band is unaffected by this pointing error due to the larger beam size. Overall, for well-pointed, point-like sources, the absolute flux calibration is better than 6 per cent, and for extended sources where mapping is required it is better than 7 per cent.
- ItemThe data processing pipeline for the Herschel SPIRE Fourier Transform Spectrometer(Oxford University Press, 2016) Fulton, T.; Naylor, David A.; Polehampton, E. T.; Valtchanov, I.; Hopwood, R.; Lu, N.; Baluteau, J.-P.; Mainetti, G.; Pearson, C.; Papageorgiou, A.; Guest, S.; Zhang, L.; Imhof, P.; Swinyard, B. M.; Griffin, M. J.; Lim, T. L.We present the data processing pipeline to generate calibrated data products from the Spectral and Photometric Imaging Receiver (SPIRE) imaging Fourier Transform Spectrometer on the Herschel Space Observatory. The pipeline processes telemetry from SPIRE observations and produces calibrated spectra for all resolution modes. The spectrometer pipeline shares some elements with the SPIRE photometer pipeline, including the conversion of telemetry packets into data timelines and calculation of bolometer voltages. We present the following fundamental processing steps unique to the spectrometer: temporal and spatial interpolation of the scan mechanism and detector data to create interferograms; Fourier transformation; apodization; and creation of a data cube. We also describe the corrections for various instrumental effects including first- and second-level glitch identification and removal, correction of the effects due to emission from the Herschel telescope and from within the spectrometer instrument, interferogram baseline correction, temporal and spatial phase correction, non-linear response of the bolometers, and variation of instrument performance across the focal plane arrays. Astronomical calibration is based on combinations of observations of standard astronomical sources and regions of space known to contain minimal emission.
- ItemSystematic characterization of the Herschel SPIRE Fourier Transform Spectrometer(Oxford University Press, 2015) Hopwood, R.; Polehampton, E. T.; Valtchanov, I.; Swinyard, B. M.; Fulton, T.; Lu, N.; Marchili, N.; van der Wiel, M. H. D.; Benielli, D.; Imhof, P.; Baluteau, J.-P.; Pearson, C.; Clements, D. L.; Griffin, M. J.; Lim, T. L.; Makiwa, G.; Naylor, David A.; Noble, G.; Puga, E.; Spencer, Locke DeanA systematic programme of calibration observations was carried out to monitor the performance of the Spectral and Photometric Imaging REceiver (SPIRE) Fourier Transform Spectrometer (FTS) instrument on board the Herschel Space Observatory. Observations of planets (including the prime point-source calibrator, Uranus), asteroids, line sources, dark sky and cross-calibration sources were made in order to monitor repeatability and sensitivity, and to improve FTS calibration. We present a complete analysis of the full set of calibration observations and use them to assess the performance of the FTS. Particular care is taken to understand and separate out the effect of pointing uncertainties, including the position of the internal beam steering mirror for sparse observations in the early part of the mission. The repeatability of spectral-line centre positions is <5kms−1, for lines with signal-to-noise ratios>40, corresponding to <0.5–2.0 percent of a resolution element. For spectral-lineflux,the repeatability is better than 6percent, which improves to 1–2percent for spectra corrected for pointing offsets. The continuum repeatability is 4.4percent for the SPIRE Long Wavelength spectrometer (SLW) band and 13.6percent for the SPIRE Short Wavelength spectrometer (SSW) band, which reduces to ∼1percent once the data have been corrected for pointing offsets. Observations of dark sky were used to assess the sensitivity and the systematic offset in the continuum, both of which were found to be consistent across the FTS-detector arrays. Theaveragepoint-sourcecalibratedsensitivityforthecentredetectorsis0.20and0.21Jy[1σ; 1h],forSLWandSSW.Theaveragecontinuumoffsetis0.40JyfortheSLWbandand0.28Jy for the SSW band.